No | Part number | Description ( Function ) | Manufacturers | |
5 | ADAS1000 | Five Electrode Electrocardiogram (ECG) Analog Front End Data Sheet Low Power, Five Electrode Electrocardiogram (ECG) Analog Front End ADAS1000/ADAS1000-1/ADAS1000-2 FEATURES Biopotential signals in; digitized signals out 5 acquisition (ECG) channels and one driven lead Parallel ICs for up to 10+ electrode measurements Master ADAS1000 or ADAS1000-1 used with slave ADAS1000-2 AC and dc lead-off detection Internal pace detection algo |
Analog Devices |
|
4 | ADAS1000-1 | Five Electrode Electrocardiogram (ECG) Analog Front End Data Sheet Low Power, Five Electrode Electrocardiogram (ECG) Analog Front End ADAS1000/ADAS1000-1/ADAS1000-2 FEATURES Biopotential signals in; digitized signals out 5 acquisition (ECG) channels and one driven lead Parallel ICs for up to 10+ electrode measurements Master ADAS1000 or ADAS1000-1 used with slave ADAS1000-2 AC and dc lead-off detection Internal pace detection algo |
Analog Devices |
|
3 | ADAS1000-2 | Five Electrode Electrocardiogram (ECG) Analog Front End Data Sheet Low Power, Five Electrode Electrocardiogram (ECG) Analog Front End ADAS1000/ADAS1000-1/ADAS1000-2 FEATURES Biopotential signals in; digitized signals out 5 acquisition (ECG) channels and one driven lead Parallel ICs for up to 10+ electrode measurements Master ADAS1000 or ADAS1000-1 used with slave ADAS1000-2 AC and dc lead-off detection Internal pace detection algo |
Analog Devices |
|
2 | ADAS1000-3 | Three Electrode Electrocardiogram (ECG) Analog Front End Data Sheet Low Power, Three Electrode Electrocardiogram (ECG) Analog Front End ADAS1000-3/ADAS1000-4 FEATURES Biopotential signals in; digitized signals out 3 acquisition (ECG) channels and one driven lead Can be ganged for 8 electrode + RLD using master ADAS1000 or ADAS1000-1 AC and DC lead-off detection Internal pace detection algorithm on 3 leads Support for user’s own p |
Analog Devices |
|
1 | ADAS1000-4 | Three Electrode Electrocardiogram (ECG) Analog Front End Data Sheet Low Power, Three Electrode Electrocardiogram (ECG) Analog Front End ADAS1000-3/ADAS1000-4 FEATURES Biopotential signals in; digitized signals out 3 acquisition (ECG) channels and one driven lead Can be ganged for 8 electrode + RLD using master ADAS1000 or ADAS1000-1 AC and DC lead-off detection Internal pace detection algorithm on 3 leads Support for user’s own p |
Analog Devices |
List of most widely used semiconductors
Part Number | Function | Manufacturers | |
1N4007 | The 1N4007 is a rectification diode that is designed for high-voltage applications, typically up to 1000V. It has a maximum current rating of 1A and a forward voltage drop of around 0.7V. |
Vishay |
|
LM317 | This is a popular adjustable voltage regulator. |
ON Semiconductor |
|
6N137 | LM393 | 2N3906 | 2N2222 | TIP120 | 1N5818 | LM324N | A1015 | SMAJ20CA |