Preview 1 page No Preview Available ! BCD DECADE COUNTERS/
4-BIT BINARY COUNTERS
The LS160A / 161A / 162A / 163A are high-speed 4-bit synchronous count-
ers. They are edge-triggered, synchronously presettable, and cascadable
MSI building blocks for counting, memory addressing, frequency division and
other applications. The LS160A and LS162A count modulo 10 (BCD). The
LS161A and LS163A count modulo 16 (binary.)
The LS160A and LS161A have an asynchronous Master Reset (Clear)
input that overrides, and is independent of, the clock and all other control
inputs. The LS162A and LS163A have a Synchronous Reset (Clear) input that
overrides all other control inputs, but is active only during the rising clock
edge.
BCD (Modulo 10)
Binary (Modulo 16)
Asynchronous Reset
LS160A
LS161A
Synchronous Reset
LS162A
LS163A
• Synchronous Counting and Loading
• Two Count Enable Inputs for High Speed Synchronous Expansion
• Terminal Count Fully Decoded
• Edge-Triggered Operation
• Typical Count Rate of 35 MHz
• ESD > 3500 Volts
CONNECTION DIAGRAM DIP (TOP VIEW)
VCC TC Q0 Q1 Q2 Q3 CET PE
16 15 14 13 12 11 10 9
1 2 3 4 56 78
*R CP P0 P1 P2 P3 CEP GND
NOTE:
The Flatpak version
has the same pinouts
(Connection Diagram) as
the Dual In-Line Package.
*MR for LS160A and LS161A
*SR for LS162A and LS163A
PIN NAMES
PE
P0 – P3
CEP
CET
CP
MR
SR
Q0 – Q3
TC
Parallel Enable (Active LOW) Input
Parallel Inputs
Count Enable Parallel Input
Count Enable Trickle Input
Clock (Active HIGH Going Edge) Input
Master Reset (Active LOW) Input
Synchronous Reset (Active LOW) Input
Parallel Outputs (Note b)
Terminal Count Output (Note b)
NOTES:
a) 1 TTL Unit Load (U.L.) = 40 µA HIGH/1.6 mA LOW.
b) The Output LOW drive factor is 2.5 U.L. for Military (54) and
Temperature Ranges.
LOADING (Note a)
HIGH
LOW
1.0 U.L.
0.5 U.L.
0.5 U.L.
1.0 U.L.
0.5 U.L.
0.5 U.L.
1.0 U.L.
10 U.L.
10 U.L.
0.5 U.L.
0.25 U.L.
0.25 U.L.
0.5 U.L.
0.25 U.L.
0.25 U.L.
0.5 U.L.
5 (2.5) U.L.
5 (2.5) U.L.
5 U.L. for Commercial (74)
74LS160
74LS161
74LS162
74LS163
BCD DECADE COUNTERS /
4-BIT BINARY COUNTERS
LOW POWER SCHOTTKY
16
1
J SUFFIX
CERAMIC
CASE 620-09
16
1
N SUFFIX
PLASTIC
CASE 648-08
16
1
D SUFFIX
SOIC
CASE 751B-03
ORDERING INFORMATION
SN54LSXXXJ Ceramic
SN74LSXXXN Plastic
SN74LSXXXD SOIC
LOGIC SYMBOL
934 56
7
PE P0 P1 P2 P3
CEP
10 CET
TC 15
2 CP
*R Q0 Q1 Q2 Q3
1 14 13 12 11
VCC = PIN 16
GND = PIN 8
*MR for LS160A and LS161A
*SR for LS162A and LS163A
www.sycelectronica.com.ar
http://www.Datasheet4U.com
|
|
SN54/74LS160A • SN54/74LS161A
SN54/74LS162A • SN54/74LS163A
AC SETUP REQUIREMENTS (TA = 25°C)
Symbol
Parameter
tWCP
Clock Pulse Width Low
tW MR or SR Pulse Width
ts Setup Time, other*
ts Setup Time PE or SR
th Hold Time, data
th Hold Time, other
trec Recovery Time MR to CP
*CEP, CET or DATA
Limits
Min Typ Max
25
20
20
25
3
0
15
Unit
ns
ns
ns
ns
ns
ns
ns
Test Conditions
VCC = 5.0 V
DEFINITION OF TERMS
SETUP TIME (ts) — is defined as theminimum time required
for the correct logic level to be present at the logic input prior to
the clock transition from LOW to HIGH in order to be recog-
nized and transferred to the outputs.
HOLD TIME (th) — is defined as the minimum time following
the clock transition from LOW to HIGHthat the logic level must
be maintained at the input in order to ensure continued recog-
nition. A negative HOLD TIME indicates that the correctlogic
level may be released prior to the clock transition from LOW to
HIGH and still be recognized.
RECOVERY TIME (trec) — is defined as the minimum time re-
quired between the end of the reset pulse and the clock transi-
tion from LOW to HIGH in order to recognize and transfer
HIGH Data to the Q outputs.
AC WAVEFORMS
tW(H)
tW(L)
CP 1.3 V
tPHL
1.3 V OTHER CONDITIONS:
PE = MR (SR) = H
tPLH CEP = CET = H
Q 1.3 V
1.3 V
Figure 1. Clock to Output Delays, Count
Frequency, and Clock Pulse Width
MR 1.3 V
tW
CP
Q0 ⋅ Q1 ⋅ Q2 ⋅ Q3
tPHL
trec
1.3 V
OTHER CONDITIONS:
PE = L
P0 = P1 = P2 = P3 = H
1.3 V
Figure 2. Master Reset to Output Delay, Master Reset
Pulse Width, and Master Reset Recovery Time
www.sycelectronica.com.ar
Preview 5 Page |
Part DetailsOn this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for 74LS161 electronic component. |
Information | Total 6 Pages | |
Link URL | [ Copy URL to Clipboard ] | |
Download | [ 74LS161.PDF Datasheet ] |
Share Link :
Electronic Components Distributor
An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists. |
SparkFun Electronics | Allied Electronics | DigiKey Electronics | Arrow Electronics |
Mouser Electronics | Adafruit | Newark | Chip One Stop |
Featured Datasheets
Part Number | Description | MFRS |
74LS16 | The function is HEX INVERTER BUFFERS/DRIVERS. Texas Instruments | |
74LS160 | The function is BCD DECADE COUNTERS / 4-BIT BINARY COUNTERS. SYC | |
74LS160 | The function is BCD DECADE COUNTERS/ 4-BIT BINARY COUNTERS. ON Semiconductor | |
Semiconductors commonly used in industry:
1N4148 |  
BAW56 |
1N5400 |
NE555 | | ||
Quick jump to:
74LS
1N4
2N2
2SA
2SC
74H
BC
HCF
IRF
KA |