PCB Power Relay
16 A High Switching Current,
General-purpose Latching Relay
• Creepage distance 8 mm between coil and contacts.
• 10 kV Impulse withstand voltage.
• Ambient Operating Temperature 85°C
• Suitable for TV-8 rating. (SPST-NO (1a))
RoHS Compliant
Model Number Legend
G5RL-@@@-@
123 4
1. Relay Function
U : Single-winding latching
K : Double-winding latching
3. Contact Form
None: SPDT (1c)
A : SPST-NO (1a)
2. Number of poles
1 : 1-Pole
4. Classification
E : High-capacity
Application Examples
• Housing equipments
• Building Automation
• UPS, FA equipment
• Electric power meter
G
5
R
L
U
/
K
Ordering Information
Classification Terminal Shape Contact form Enclosure rating
Single-winding latching
Model
Rated coil voltage
Double-winding latching
Model
Rated coil voltage
High-capacity PCB terminals
SPST-NO
(1a)
Flux protection
G5RL-U1A-E
3 VDC
5 VDC
6 VDC
G5RL-K1A-E
5 VDC
12 VDC
SPDT (1c)
G5RL-U1-E
12 VDC
24 VDC
G5RL-K1-E
24 VDC
Note. When ordering, add the rated coil voltage to the model number.
Example: G5RL-U1A-E DC5
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Minimum
packing unit
100 pcs/tray
Ratings
Coil
Single-winding Latching Type
Rated Voltage
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
Rated current
(mA)
200
120
100
50
25
Coil resistance
(Ω)
15
41.7
60
240
960
Must set
voltage
Must reset
voltage
% of rated voltage
Max voltage
70% max.
70% max.
130%
Power
consumption
(W)
Approx. 0.6
Double-winding Latching Type
Rated Voltage
5 VDC
12 VDC
24 VDC
Rated current
(mA)
Set coil
Reset coil
150
62.5
35
Coil resistance (Ω)
Set coil
Reset coil
33.3
192
686
Must set
voltage
Must reset
voltage
Max voltage
% of rated voltage
70% max.
70% max.
130%
Power consumption
(W)
Set coil
Reset coil
Approx. 0.75
Approx. 0.84
1

line_dark_gray
G5RL-U equivalent
G5RL-U/-K
PCB Power Relay
Approved Standards
UL Recognized (File No. E41643) and
Model
Contact form
Coil ratings
G5RL-U1A-E
G5RL-K1A-E
G5RL-U1-E
G5RL-K1-E
SPST-NO (1a)
SPDT (1c)
5 to 24 VDC
( “-U” models:
3 to 24 VDC)
CSA Certified (File No. LR31928)
Contact ratings
16 A 277 VAC (Resistive) - NO 85°C
TV-5 - NO 40°C
TV-8 - NO 40°C
8 A 250 VAC (Ballast) - NO 40°C
2,000 W 250 VAC (Tungsten) 70°C
16 A 277 VAC (Resistive) - NO 85°C
8 A 250 VAC (Ballast) - NO 40°C
2,000 W 250 VAC (Tungsten) - NO 40°C
5 A 250 VAC (General) - NC 40°C
VDE Certified (EN61810-1) (License No. 40007172)
Model
G5RL-U1A-E
G5RL-K1A-E
G5RL-U1-E
G5RL-K1-E
Contact form
SPST-NO (1a)
SPDT (1c)
Coil ratings
5, 12, 24 VDC
( “-U” models:
3, 5, 6, 12, 24 VDC)
Contact ratings
16 A 250 VAC (cosφ=1) - NO 85°C
240 VAC 100 A (0-P) Steady 10 A (rms) - NO 85°C
16 A 250 VAC (cosφ=1) - NO 85°C
5 A 250 VAC (cosφ=1) - NC 85°C
Number of test operations
50,000
25,000
25,000
6,000
6,000
50,000
6,000
6,000
50,000
Number of test operations
30,000
50,000
30,000
30,000
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
Basic Operation of Latching Relays
• In these Relays, the input pulse of the set coil causes the
operating condition to be maintained magnetically or
mechanically, whereas the input pulse to the reset coil side
puts the Relay into the reset condition.
Set input
Reset input
NO contact
NC contact
Coil Temperature Rise of long time continuous current to
the coil
• When the coil is applied continuous current for a long time, the
coil would be heat too much.
Please decide the coil Input pulse width by “heat and cold of
coil temperature”
heat and cold of coil temperature
100
80
60
40
20
Wiring of High-capacity Models (-E)
• High-capacity models (-E) have a structure that connects two
terminals from one contact. When designing the circuit, use
both terminals. If you use only one terminal, the Relay may be
unable to satisfy specified performance.
Precautions for Correct Use
• This product is not suitable for vehicles such as automobiles
(including two-wheeled vehicles).
• If the product is used in the following applications, consult your
OMRON sales representative to check the necessary items
according to the specification sheets.Also make sure the
product is used within the specified ratings and performance
ranges with an ample margin and implement safety measures,
such as designing a safety circuit, to minimize danger should
the product fail.
a. Outdoor use, uses involving potential chemical
contamination or electrical interference.
b. Nuclear energy control systems, combustion systems,
railroad systems, aviation systems, medical equipment,
safety equipment, and equipment that could present a risk
to human life or body.
c. Equipment requiring a high level of reliability, such as gas,
water, or electrical supply systems.
G
5
R
L
U
/
K
0
0 5 10 15 20 25 30 35 40 45 50 55 60
Time (minute)
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K265-E1-06
0316(0913)(O)
5


line_dark_gray

Preview 5 Page


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for G5RL-U electronic component.


Information Total 5 Pages
Link URL [ Copy URL to Clipboard ]
Download [ G5RL-U.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
G5RL-KThe function is PCB Power Relay. OmronOmron
G5RL-UThe function is PCB Power Relay. OmronOmron

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

G5RL     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search